• 首页|编委会|期刊简介|期刊荣誉|投稿指南|联系我们|过刊浏览
刘爽,徐红梅,李航,王成龙,姜威,董佳俊.手扶插秧机手传振动评价及振动传递特性试验[J].华中农业大学学报,2020,39(1):151-160
手扶插秧机手传振动评价及振动传递特性试验
Hand vibration transmission evaluation and vibration transmission characteristics test of hand-held rice transplanter
投稿时间:2019-03-11  
DOI:
中文关键词:  手扶插秧机  手传振动  振动响应  日振动暴露量  振动传递  手传振动病
英文关键词:hand-held rice transplanter  hand-transmitted vibration  vibration response  daily vibration exposure  vibration transmission  hand-transmitted vibration disease
基金项目:国家自然科学基金面上项目(51875230);国家自然科学基金青年基金项目(51405178)
作者单位E-mail
刘爽 华中农业大学工学院/农业农村部长江中下游农业装备重点实验室武汉 430070 liushuang187@126.com 
徐红梅 华中农业大学工学院/农业农村部长江中下游农业装备重点实验室武汉 430070 xhm790912@163.com 
李航 华中农业大学工学院/农业农村部长江中下游农业装备重点实验室武汉 430070  
王成龙 华中农业大学工学院/农业农村部长江中下游农业装备重点实验室武汉 430070  
姜威 华中农业大学工学院/农业农村部长江中下游农业装备重点实验室武汉 430070  
董佳俊 华中农业大学工学院/农业农村部长江中下游农业装备重点实验室武汉 430070  
摘要点击次数: 134
全文下载次数: 104
中文摘要:
      以某手扶插秧机手柄和接振人员手臂为研究对象,采用基于振动总值的日振动暴露量的评价方法对手扶插秧机在2种不同工况下的手传振动进行了复合试验评价,计算结果显示,该手扶插秧机日振动暴露量为2.442 m/s2,满足欧盟指令规定的要求。对人体手臂进行了振动响应分析和振动传递特性分析,结果表明,在2种工况下手扶插秧机手柄处的振动传递到手臂上时,振动呈逐渐衰减的趋势;操作手扶插秧机时,手腕对振动能量的吸收最多;手部对8~16 Hz和100 Hz附近的振动能量吸收较差,考虑到100 Hz左右的中频振动是造成雷诺氏症的主要原因,因此,100 Hz左右的中频振动应为今后插秧机扶手振动研究控制的重点。
英文摘要:
      Taking the handle of a hand-held rice transplanter and the arm of a vibration receiver as the research object,the hand-transmitted vibration of the hand-held rice transplanter under two different working conditions was evaluated by using the method of daily vibration exposure based on the total vibration value. The results of calculation showed that the daily vibration exposure of the hand-held rice transplanter was 2.442 m/s2,meeting the requirements of the EU directive. The results of analyzing the vibration response and transmission characteristics of human arm showed that when the vibration at the handle of the hand-held rice transplanter was transmitted to the arm under two working conditions,the vibration was gradually attenuated. When operating the hand -held rice transplanter,the wrist absorbed the most vibration energy. The hand had poor absorption of vibration energy around 8-16 Hz and 100 Hz. Considering that the middle frequency vibration around 100 Hz is the main cause of Raynaud’s disease,the medium frequency vibration of about 100 Hz should be the focus of research and control of the hand-transmitted vibration of the transplanter in the future.
查看全文  查看/发表评论  下载PDF阅读器
关闭
版权所有:华中农业大学学报(自然科学版)  
主管单位:华中农业大学 主办单位:华中农业大学 地址:湖北武汉南湖狮子山华中农业大学内
电话:027-87287364 电子邮件:hnlkxb@mail.hzau.edu.cn
您是本站第8494335位访问者  今日一共访问3186次  
技术支持:北京勤云科技发展有限公司